Products
60W Single Output Switching Power Supply
Model:HLG-60H-15
Features
- Universal AC input / Full range(up to 305VAC)
- Built-in active PFC function
- Protections: Short circuit / over current / over voltage / over temp.
- Cooling by free air convection
- IP67/IP65 design for indoor or outdoor installations
- Class 2 power unit
Description
HLG-60H-15is a 60W single output switching power supply,this product allows the universal AC input voltage range of 90~305 VAC or 127~431 VAD.Designed with IP67/IP65 for outdoor and indoor installations and provide fundamental resistance to moisture and dust.
Specifications

Model | HLG-60H-15 |
DC voltage | 15V |
Rated current | 4A |
Rated power | 60W |
Voltage range | 90〜305VAC 或 127〜431VDC |
Over current | 95〜108% |
Over current | Protection type : Constant current limiting, recovers automatically after fault condition is removed |
Frequency range | 47〜63Hz |
Short circuit | Hiccup mode, recovers automatically after fault condition is removed |
Over voltage | 18〜24V。 |
Over voltage | Protection type : Shut down o/p voltage, re-power on to recover |
EMC emission | Compliance to EN55015, EN61000-3-2 Class C (≧60% load) ; EN61000-3-3 |
EMC immunity | Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level (surge 4KV), criteria A |
Packing | 0.73Kg; 20pcs/15.6Kg/0.8CUFT |
MTBF (mean time between failure) | 338Khrs min. MIL-HDBK-217F (25℃) |
Constant current region | 9〜15V |
Ripple & noise (max.) | 150mVp-p |
Voltage ADJ. range | 13.5〜17V |
Current ADJ. range | 2.4〜4A |
Voltage tolerance | ±2.0% |
Line regulation | ±0.5% |
Load regulation | ±1.5% |
Setup, rise time | 500ms, 80ms at full load 。230VAC / 115VAC |
Hold up time | 16ms/230VAC 。16ms/115VAC at full load |
Power factor | PF>0.98/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load |
Total harmonic distortion | THD< 20% when output loading≧60% at 115VAC/230VAC input and output loading≧75% at 277VAC input |
Efficiency | 87.5% |
AC current | 0.64A / 115VAC 0.32A / 230VAC 0.3A / 277VAC |
Inrush current | COLD START 55A(twidth=265 s measured at 50% Ipeak) at 230VAC |
Max. No. of PSUs on 16A circuit breaker | 9 units (circuit breaker of type B) / 16 units (circuit breaker of type C) at 230VAC |
Leakage current | <0.75mA / 277VAC |
Temp. coefficient | ±0.03%/℃ (0〜60℃) |
Vibration | 10〜500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes |
Over temperature | Shut down o/p voltage, re-power on to recover |
Safety standards | UL8750(type”HL”), CSA C22.2 No. 250.0-08 (except for 48V, 54V), EN61347-1, EN61347-2-13 independent, IP65 or IP67, J61347-1, J61347-2-13 approved ; design refer to UL60950-1, TUV EN60950-1, EN60335-1 |
Withstand voltage | I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC |
Isolation resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH |
Operating humidity | 20〜95% RH non-condensing |
Operating temperature | -40〜+70℃ |
Storage Humidity | 10〜95% RH |
Storage temperature | -40〜+85℃ |
Dimensions | 171*61.5*36.8mm (L*W*H) |