| Protocols | CSMA/CD |
| IEEE Standard | IEEE 802.3 10Base-T Ethernet |
| IEEE Standard | IEEE 802.3u 100Base-TX Fast Ethernet |
| IEEE Standard | IEEE 802.3ab 1000Base-T Gigabit Ethernet |
| IEEE Standard | IEEE 802.3z 1000Base-X Gigabit Ethernet |
| IEEE Standard | IEEE802.3af for POE。IEEE802.3at for POE+ |
| MAC address table size | 2K |
| Network connector | 1xRJ-45 10/100/1000BaseT(X) PSE with PoE |
| Network connector | Output power up to 36Watts |
| Network connector | 1 x 100/1000M SFP |
| Housing design | Rugged Metal, IP30 Protection |
| Power Consumption | 2 W@48 VDC Without POE |
| Network Cable | UTP/STP above Cat.5e Cable |
| Network Cable | EIA/TIA-568 10-ohm (100m) |
| Switch Architecture | Back-plane (Switching Fabric): 4Gbps |
| Packet Buffer Size | 1M |
| Data Processing | Store and Forward |
| LEDs | PW1(power 1) Green: ON- power good, OFF-power failed |
| LEDs | UTP LED: Amber ON - PD detected / Green ON – Link/active |
| LEDs | SFP LED: Green ON – SFP detected |
| POE power | Maximum POE power 36watts at 56VDC input |
| Reserve polarity protection & Overload current protection | Present |
| Removable terminal block | Provide 4 pin terminal block / Wire range: 0.34mm^2 to 2.5mm^2 |
| Removable terminal block | Solid wire (AWG):12-24/14-22 / Stranded wire(AWG): 12-24/14-22 |
| Removable terminal block | Torque:5lb-In/0.5Nm/0.56Nm / Wire Strip length: 7-8mm |
| MTBF (mean time between failure) | 510,304 hrs ( MIL-HDBK-217F) at 25°C |
| EN55022/24 (Certifications) | ITE equipment |
| EN55011 (Certifications) | Industrial, Scientific and Medical (ISM) equipment |
| Safety (Certifications) | IEC EN60950-1 |
| EMC/EMS (Certifications) | CE, FCC, VCCI |
| (Certifications) EMI | FCC Part 15 Subpart B Class A, CE EN 55022 Class A |
| EN 50155 / EN 60068-2-6 (Certifications) | Vibration |
| EN 50155 /EN 60068-2-27 (Certifications) | Shock |
| EN 50155 / EN 60068-2-32 (Certifications) | Free Fall |
| Alarm Relay Contact | Relay outputs with current carrying capacity of 1 A @24VDC, Relay in short circuit mode when power fails. in open circuit mode when power supply is connected |
| Installation | DIN Rail mounting and Wall Mounting |
| Flow Control | IEEE 802.3x Flow Control and Back Pressure |
| Jumbo Frame | 9KB |
| DIP switch | To select SFP speed 100M or 1000M |
| PoE Pin Assignment | 30 watts 2 pairs Mode A End Span / V+, V+, V-, V- for pin 1, 2, 3, 6 |
| Operating humidity | 5% to 95% (Non-condensing) |
| Operating temperature | 40℃〜75℃ fully tested |
| Storage temperature | -40℃〜85℃ |
| Dimensions | 103.5mmx32mmx81.5mm |
| Power Supply | 4 pin terminal block with 48V-56V VDC Power Input, SW ( Relay ): Relay switch for alarm |
| Warranty | 1 Year |